Each Sheet sets its code notes for the job's US state or Canadian province. These are the model-code numbers it starts from (the IRC in the US, the NBC in Canada, with Ontario's differences) and the local figures we found. Towns amend the codes, so confirm with your building department before you dig or frame.

Code reference · 011. How deep footings go (frost depth)

1. How deep footings go (frost depth)

Footings for decks, deck stairs, additions and concrete piers go below the frost line, and in the US at least 12″ below undisturbed ground either way (IRC R403.1.4). Each jurisdiction sets its own depth (IRC Table R301.2), so most of these are one town's figure, as an example of the area.

WhereDepthWhat the figure is
Minnesota42″ in southern counties (Hennepin, Ramsey) to 60″ in northern ones (St. Louis)State rule, Minn. R. 1303.1600
Massachusetts48″Statewide, 780 CMR 51
New Hampshire48″Durham, for example
Michigan, Illinois, Iowa, upstate New York42″One county or town in each, for example
New Jersey36″ in the north and center, 30″ in the southAsk your town's construction office
New York CitySet by the NYC Building CodeAsk the NYC Department of Buildings
Colorado36″Littleton, for example
Virginia24″City of Fairfax, for example
Ontario1.2 m (47¼″)Ontario municipal deck guides
Alberta, Nova Scotia1.2 mAlberta's deck guidance and Calgary; Halifax
Manitoba1.8 m (70⅞″)Manitoba's deck guide and Winnipeg
British ColumbiaAbout 457 mm (18″) on the south coast; 610–760 mm around Squamish–Lillooet; deeper northMunicipal footing guides
Code reference · 022. Stairs, handrails and guards

2. Stairs, handrails and guards

For inside stairs, deck stairs, concrete steps, steel and spiral stairs and railings and guards. US numbers are the IRC 2021 (the 2024 IRC keeps them under new section numbers: stairs R318.7, guards R321); Canada is the NBC 2020 Part 9 for stairs in a house.

United States (IRC)Canada (NBC 2020)
Riser7¾″ (196 mm) at most125–200 mm (4.9–7.9″)
Tread or runTread at least 10″Run 255–355 mm (10–14″)
Riser and tread differences⅜″ at most within a flight5 mm between steps next to each other, 10 mm across the flight
Headroom6′ 8″1950 mm (6′ 4¾″)
Handrail height34–38″865–1070 mm
Handrail needed4 or more risersInside: more than 2 risers. Outside: more than 3
Guard neededA drop of more than 30″ within 36″ of the edgeA drop of more than 600 mm (23⅝″)
Guard height36″ (34″ along the stairs)900 mm; 1070 mm (42″) outside where the deck is more than 1.8 m up
Openings in the guardA 4″ sphere can't pass; 4⅜″ on the stairs; 6″ in the triangle under the stair's bottom rail100 mm (Ontario: 150 mm in the triangle at the stair)
No-climb zoneNone140–900 mm above the floor where the drop is more than 4.2 m. Ontario: at any height

New York and Virginia allow 8¼″ risers and 9″ treads, and some towns ask for 42″ guards. Quebec houses of 2 storeys or fewer follow municipal bylaws; StudSheet uses the NBC numbers there until checked.

Code reference · 033. Basement wall insulation

3. Basement wall insulation

When you finish a basement, the energy code sets the wall insulation. In the US it's the IECC 2021 (Table R402.1.3), by climate zone; your county sets the zone.

US climate zoneBasement walls
0–2 (Florida, Hawaii, the Gulf Coast)No minimum
3R-5 continuous or R-13 between studs
4, except the Pacific Northwest coast (New Jersey is 4A)R-10 continuous or R-13 between studs
4 Marine (coastal Washington and Oregon), and 5–8R-15 continuous or R-19 between studs or R-13 plus R-5 continuous

California enforces its own energy code (Title 24): ask your building department.

Canada: the NBC 2020 (9.36) sets an effective value for the whole wall, studs included: RSI 1.99 (R-11.3) in zone 4, RSI 2.98 (R-16.9) in zones 5 and 6, and up to RSI 3.97 (R-22.5) in zone 8 without a heat-recovery ventilator. Ontario (2024 OBC with SB-12): most packages need R-20 continuous, or R-12 plus R-10 continuous, over the full height of the wall. Quebec: total RSI 2.99 (R-17).

Code reference · 044. When a retaining wall needs a permit

4. When a retaining wall needs a permit

For garden and retaining walls:

  • United States: the IRC exempts walls 4 ft or less from the bottom of the footing to the top, unless they hold back a surcharge (a driveway, a slope, a building) (R105.2). A wall retaining more than 48″ of fill, or more than 24″ with a surcharge, needs a design (R404.4). Towns vary: in New Jersey terraced walls are added together.
  • Canada: the NBC sets no general height; provinces and cities do. - Ontario: a wall over 1.0 m next to public property, a building's entrance or a public area is a "designated structure": permit, professional drawings and guards. - Calgary: 1.2 m or more, with walls within 1 m of each other counted together. - Alberta: any wall that holds up a building's foundation, or over 1.2 m next to public areas. - Burnaby: over 1.2 m, engineer-sealed. - Halifax: over 1 m on a serviced lot. - Montreal area: 1 m in Baie-D'Urfé and Terrebonne; boroughs differ.
Code reference · 05Questions

Questions

How does StudSheet know my state or province's rules?

Set the job's US state or Canadian province (or switch any Sheet between US feet and inches and Canadian metric). The Sheet then uses that place's frost depth, stair and guard numbers, basement insulation, bag sizes (80 lb in the US, 30 kg in Canada), utility locate (811 in the US, the provincial service in Canada) and lead-paint year (before 1978 in the US, before 1990 in Canada).

Do StudSheet's code notes replace my building inspector?

No. Towns, counties and municipalities amend the IRC, NEC, NBC and provincial codes. The notes give you the model-code numbers and the local figures we found, so you plan the job right; the building department has the final word, and every Sheet says so.

Get the Sheet.

Open StudSheet
Coming soon on theApp StoreComing soon onGoogle Play