Sheet S-21 · Water heater replacement
Gas water heater, 4 people
- Size
- 50 galfirst hour 84 gal
- Busiest hour
- 83 gal4 showers
- Vent
- 3″Type B
- Expansion
- 2 galcheck the main
Tools you need
- Appliance dolly
- Pipe wrenches (14″ + 18″)
- Tongue-and-groove pliers
- Tubing cutter
- Cordless drill/driver
- 4-ft level
15 tools on the Sheet, each marked own, buy or rent
| Buy | Item | How we got this |
|---|---|---|
| 1 heater | Gas water heater, 50 gal, atmospheric vent50 gal, atmospheric vent, about 40,000 BTU/h, first-hour rating 84 gal | Busiest hour (DOE worksheet, hot water per use): 4 showers × 20 gal + kitchen 3 gal = 83 gal. A 50 gal gas tank rates about 84 gal in its first hour, the smallest that covers it. 4 people and 2 baths: everyone showers in that hour, at most 2 per bathroom. |
| 1 valve | Ball valve, ¾ in¾″ full port | Cold shutoff at the heater. |
| 2 connectors | Water heater connectors¾″ × 18″ | Hot and cold (or hard pipe). |
| 1 length of 10′ | Copper pipe, type L, ¾ in¾″ copper, type L | Down the side of the tank to a floor drain or the floor: about 6 ft. Copper, CPVC or PEX rated for relief lines — never PVC. |
| 3 fittings | Copper fittings (sweat or press)¾″ | Male adapter at the valve and two elbows (sweat or press). |
| 1 tank | Thermal expansion tank, 2 gal2 gal, potable | Sized on the makers’ charts: about 2 gal for a 40–50 gal tank, 4.5 gal for bigger tanks or high pressure. Likely needed: check the meter and the main for a check valve or PRV. |
| 1 valve | Gas appliance shutoff valvesized by the gas fitter | Appliance shutoff in the same room, within reach of the unit. |
| 1 set | Sediment trap (drip leg) fittingssized by the gas fitter | Tee, nipple and cap ahead of the gas valve: dirt in the gas drops out here. |
| 1 connector | Gas appliance connectorrated for the input | Listed connector or hard pipe — the gas fitter’s call. |
| 1 roll | Gas-rated thread sealantgas-rated | Yellow PTFE tape or pipe dope listed for gas. |
| 1 bottle | Gas leak detector solutionbubble solution | Every gas joint, before and after lighting. |
| 6 ft in sections | Type B gas vent, 3 in3″, Type B | Vent connector from the draft hood to the chimney or vent: 6 ft. Match the draft hood outlet; never smaller. |
| 2 elbows | Type B vent elbows3″ | Adjustable elbows off the draft hood and into the vent. |
| 1 haul-away | Haul-away of the old water heaterold unit | Scrap-metal recycling or the dump fee; many suppliers take the old tank when they deliver. |
Sheet S-21 · Water heater replacement
Gas water heater, 4 people
- Size
- 189 Lfirst hour 318 L
- Busiest hour
- 314 L4 showers
- Vent
- 3 inType B
- Expansion
- 7.6 Lcheck the main
Tools you need
- Appliance dolly
- Pipe wrenches (14 in + 18 in)
- Tongue-and-groove pliers
- Tubing cutter
- Cordless drill/driver
- 1.2 m level
15 tools on the Sheet, each marked own, buy or rent
| Buy | Item | How we got this |
|---|---|---|
| 1 heater | Gas water heater, 189.3 L, atmospheric vent189 L, atmospheric vent, about 11.7 kW (40,000 BTU/h), first-hour rating 318 L | Busiest hour (DOE worksheet, hot water per use): 4 showers × 76 L + kitchen 11 L = 314 L. A 189 L gas tank rates about 318 L in its first hour, the smallest that covers it. 4 people and 2 baths: everyone showers in that hour, at most 2 per bathroom. |
| 1 valve | Ball valve, ¾ in¾ in full port | Cold shutoff at the heater (OBC 7.6.1.3). |
| 2 connectors | Water heater connectors¾ in × 457 mm | Hot and cold (or hard pipe). |
| 1 length of 3.66 m | Copper pipe, type L, ¾ in¾ in copper, type L | Down the side of the tank to a floor drain or the floor: about 1.83 m. Copper, CPVC or PEX rated for relief lines — never PVC. |
| 3 fittings | Copper fittings (sweat or press)¾ in | Male adapter at the valve and two elbows (sweat or press). |
| 1 tank | Thermal expansion tank, 7.6 L7.6 L, potable | Sized on the makers’ charts: about 7.6 L for a 151–189 L tank, 17 L for bigger tanks or high pressure. Likely needed: check the meter and the main for a check valve or PRV. |
| 1 valve | Gas appliance shutoff valvesized by the gas fitter | Appliance shutoff in the same room, within reach of the unit. |
| 1 set | Sediment trap (drip leg) fittingssized by the gas fitter | Tee, nipple and cap ahead of the gas valve: dirt in the gas drops out here. |
| 1 connector | Gas appliance connectorrated for the input | Listed connector or hard pipe — the gas fitter’s call. |
| 1 roll | Gas-rated thread sealantgas-rated | Yellow PTFE tape or pipe dope listed for gas. |
| 1 bottle | Gas leak detector solutionbubble solution | Every gas joint, before and after lighting. |
| 1.83 m in sections | Type B gas vent, 3 in3 in, Type B | Vent connector from the draft hood to the chimney or vent: 1.83 m. Match the draft hood outlet; never smaller. |
| 2 elbows | Type B vent elbows3 in | Adjustable elbows off the draft hood and into the vent. |
| 1 haul-away | Haul-away of the old water heaterold unit | Rented tanks go back to the rental company instead. |