Sheet S-18 · Circuits and wiring runs
3 circuits
- Circuits
- 33 × 120 V · 0 × 240 V
- Cable
- 515ft · NM-B
- Breakers
- 33 AFCI/dual · 0 GFCI-protected
- Panel spaces
- 3of 8 open
Tools you need
- Non-contact voltage tester
- Digital multimeter
- Lockout/tagout kit
- Wire strippers
- Lineman’s pliers
- Insulated screwdrivers (1000 V)
16 tools on the Sheet, each marked own, buy or rent
| Buy | Item | How we got this |
|---|---|---|
| 515 ft — 2 × 250 ft rolls + 1 × 25 ft roll | NM cable 12/2 with groundNM-B | General receptacles: 3 × (40 ft home run + 7 × 14 ft between boxes + 18 ft slack) + 10%. Slack: 3 ft at the panel and 1 ft for every cable end in a box. |
| 24 boxes | Single-gang box, new work | One per receptacle and switch. Size each for its fill: 2.0 cu in per 14 AWG and 2.25 per 12 AWG conductor, the device counts as two (NEC 314.16). |
| 24 receptacles | Receptacle, 20 A tamper-resistant | 24 for general receptacles. 15 A receptacles are allowed on a 20 A circuit with two or more of them (NEC 210.21(B)(3)); a single receptacle on its own 20 A circuit must be 20 A. Tamper-resistant throughout a home (NEC 406.12). |
| 24 plates | Wall plates, single-gang | One per device. |
| 3 breakers | AFCI breaker (combination type)20 A | 3 for general receptacles (arc-fault). Only breakers listed for this panel’s brand and type (NEC 110.3(B)). |
| 2 packs of 100 | Cable staples (100) | About 165 staples: within 12″ of each box and every 4½ ft (NEC 334.30). |
| 3 connectors | NM cable connectors | One where each cable enters the panel, plus one per metal box. |
| 1 × 100 | Wire connectors (100) | About 3 per box (splices and ground pigtails) for 24 boxes. |
Sheet S-18 · Circuits and wiring runs
3 circuits
- Circuits
- 33 × 120 V · 0 × 240 V
- Cable
- 157m · NMD90
- Breakers
- 33 AFCI/dual · 0 GFCI-protected
- Panel spaces
- 3of 8 open
Tools you need
- Non-contact voltage tester
- Digital multimeter
- Lockout/tagout kit
- Wire strippers
- Lineman’s pliers
- Insulated screwdrivers (1000 V)
16 tools on the Sheet, each marked own, buy or rent
| Buy | Item | How we got this |
|---|---|---|
| 156.97 m — 3 × 75 m coils | NM cable 14/2 with groundNMD90 | General receptacles: 3 × (12.19 m home run + 7 × 4.27 m between boxes + 5.49 m slack) + 10%. Slack: 914 mm at the panel and 305 mm for every cable end in a box. |
| 24 boxes | Single-gang box, new work | One per receptacle and switch, each sized for its conductors and device (the CEC box-fill tables). |
| 24 receptacles | Receptacle, 15 A tamper-resistant | 24 for general receptacles. Tamper-resistant throughout a home. |
| 24 plates | Wall plates, single-gang | One per device. |
| 3 breakers | AFCI breaker (combination type)15 A | 3 for general receptacles (arc-fault). Only breakers listed for this panel’s brand and type. |
| 2 packs of 100 | Cable staples (100) | About 153 staples: within 300 mm of each box and every 1.5 m. |
| 3 connectors | NM cable connectors | One where each cable enters the panel, plus one per metal box. |
| 1 × 100 | Wire connectors (100) | About 3 per box (splices and ground pigtails) for 24 boxes. |